Tools Required
J 5403 Snap Ring
Pliers
- Coat the O-rings with
525 viscosity refrigeration oil.
- Using thumb pressure, push the O-rings in place.
Important: Seat the retaining ring properly in the ring groove.
- Using the J 5403
,
install the valve retaining ring with the high point of the curved sides against
the valve housing.
- Evacuate the system. Recharge the system.
- Perform a leak test. Refer to
Compressor Leak Testing
.