J 39500-B A/C Refrigerant Recover, Recharging, and Recycling Station
Caution: Unless directed otherwise, the ignition and start switch must be in the OFF or LOCK position, and all electrical loads must be OFF before servicing any electrical component. Disconnect the negative battery cable to prevent an electrical spark should a tool or equipment come in contact with an exposed electrical terminal. Failure to follow these precautions may result in personal injury and/or damage to the vehicle or its components.
J 39500-B A/C Refrigerant Recover, Recharging, and Recycling Station
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
• | Install the TXV fitting from the evaporator inlet line (7). |
Tighten
Tighten the fitting to 17 N·m (13 lb ft),
using a 23-mm wrench at fitting (8) and a 16-mm wrench at fitting (9).
• | Install the TXV fitting (1) to the evaporator. |
Tighten
Tighten the fitting to 24 N·m (17 lb ft),
using a 15-mm wrench at fitting (3) and a 9/16-in wrench at fitting (4).
• | Install the TXV fitting from the evaporator outlet line (2). |
Tighten
Tighten the fitting to 8 N·m (71 lb in),
using a 13-mm wrench at fitting (6) and a 19-mm wrench at fitting (5).
Tighten
Tighten the screws to 1.4 N·m (12 lb in).
A mounting screw is located in a recess in the center of the cover.
Tighten
Tighten the screws to 1.4 N·m (12 lb in).
Important: Perform a leak test on the fittings of the TXV before you finish re-assembly. You can perform this test without running the vehicle.
4.1. | Evacuate and partially recharge the A/C system using 0.48 kg (1 lb) of refrigerant R-134a. |
4.2. | Perform a leak test. Refer to Leak Testing . |