When you first turn the ignition switch to the RUN position, the inflatable restraint sensing and diagnostic module (SDM) performs tests to diagnose critical malfunctions within itself. Next the SDM measures IGNITION 1 voltage to make sure it is within its respective normal voltage range. Then the SDM proceeds with the DEPLOYMENT LOOP CONTINUITY test. During the DEPLOYMENT LOOP CONTINUITY test, the SDM measures the voltage difference between PASSENGER SENSE HIGH and PASSENGER SENSE LOW.
• | The voltage difference between PASSENGER SENSE HIGH terminal 1 and PASSENGER SENSE LOW terminal 4 is more than or equal to 400 millivolts. |
• | The malfunction must be present for at least 500 milliseconds during one of the following tests: |
- | DEPLOYMENT LOOP CONTINUITY |
- | If the malfunction is detected in this test, the RESISTANCE MEASUREMENT test will not be performed. |
- | CONTINUOUS MONITORING |
• | The SDM sets a Diagnostic Trouble Code. |
• | The SDM turns ON the AIR BAG warning lamp. |
• | Current DTC |
The voltage difference between PASSENGER SENSE HIGH terminal 1 and PASSENGER SENSE LOW terminal 4 is less than 400 millivolts for 500 milliseconds. |
• | History DTC |
- | You issue a scan tool CLEAR CODES command. |
- | Once 250 malfunction free ignition cycles have occurred. |
The following can cause an intermittent condition:
• | A poor connection at the inflatable restraint I/P module (passenger inflator module) harness connector terminals A and B. |
• | A poor connection at the SDM terminals 1 and 4. |
• | An open in CKT 1403. |
• | An open in CKT 1404. |
When measurements are requested in this table, use the J 39200 DMM with the correct terminal adapter from the J 35616 Connector Test Adapter Kit. When an inspection for proper connection is requested, refer to Testing for Electrical Intermittents in Wiring Systems. When a wire, connector or terminal repair is requested, use the J-38125 Terminal Repair Kit and refer to Wiring Repairs in Wiring Systems.
The numbers below refer to the step numbers on the diagnostic table:
This test determines the deployment loop voltage difference measured by the inflatable restraint sensing and diagnostic module (SDM).
This test checks for proper contact or corrosion of the yellow 2-way connector.
This test isolates the malfunction to one side of the inflatable restraint I/P module (passenger inflator module) yellow 2-way connector.
This test checks for proper contact or corrosion of the SDM harness connector.
This test determines whether the malfunction is in CKT 1403.
This test determines whether the malfunction is in CKT 1404.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the SIR Diagnostic System Check performed? | -- | ||
Has the PASSENGER VDIF been read and recorded on the repair order? | -- | -- | ||
Are the terminals damaged or corroded? | -- | |||
4 | Replace the inflatable restraint I/P module (passenger inflator module) yellow 2-way I/P harness connector. Refer to Wiring Repair in this section. Are the repairs complete? | -- | -- | |
5 | Check for proper connection at terminals A and B on the inflatable restraint I/P module yellow 2-way connector. Are the terminals damaged or corroded? | -- | ||
6 | Check for proper connection at terminals A and B on the inflatable restraint I/P module (passenger inflator module) yellow 2-way connector. Are the terminals damaged or corroded? | -- | ||
7 | Replace the inflatable restraint I/P module (passenger inflator module). Refer to Inflatable Restraint Instrument Panel Module Replacement . Are the repairs complete? | -- | -- | |
8 |
Is the PASSENGER VDIF less than the specified value? | 400 mV | ||
9 |
Are the repairs complete? | -- | -- | |
Is the PASSENGER VDIF less than the specified value? | 400 mV | |||
11 |
Are the repairs complete? | -- | -- | |
Is the connector damaged or corroded? | -- | |||
13 | Replace the SDM harness connector. Refer to Wiring Repair in this section. Are the repairs complete? | -- | -- | |
14 | Check for proper connection at terminals 1 and 4 of the SDM. Are the terminals damaged or corroded? | -- | ||
15 | Check for proper connection at terminals 1 and 4 of the SDM. Are the terminals damaged or corroded? | -- | ||
16 | Replace the inflatable restraint Sensing and Diagnostic Module (SDM). Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement . Are the repairs complete? | -- | -- | |
Is the resistance reading within the specified values? | 0-0.5 ohms | |||
18 | Repair the high resistance condition in CKT 1403. Are the repairs complete? | -- | -- | |
Is the resistance reading within the specified values? | 0-0.5 ohms | Go to Integrity Check | ||
20 | Repair the high resistance condition in CKT 1404. Are the repairs complete? | -- | -- | |
21 | Reconnect all the SIR system components, make sure all the components are properly mounted. Have all the SIR components been reconnected and properly mounted? | -- | -- | |
22 | Clear all the SIR DTCs. Have all the SIR DTCs been cleared? | -- | -- |