Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Fill the washer fluid level to the normal level. Does the LOW WASH indicator light continuously? | -- | Go to Step 3 | Go to Step 2 |
2 | Does the low wash indicator light when the washer solvent level is low? | -- | Refer to Instrument Cluster Operation | Go to Step 4 |
3 |
Is the low washer fluid input active? | -- | Go to Step 10 | Go to Step 5 |
4 |
Does the test light illuminate? | -- | Go to Step 6 | Go to Step 7 |
5 |
Did the indicator turn off when the switch is disconnected? | -- | Go to Step 9 | Go to Step 8 |
6 | Inspect CKT 185 for an open. Did you find and correct a condition? | -- | System OK | Go to Step 9 |
7 | Repair an open in CKT 150. Did you complete the repair? | -- | System OK | -- |
8 | Inspect CKT 185 for a short to ground. Did you find and repair a condition? | -- | System OK | Go to Step 10 |
9 | Replace the washer solvent level sensor. Refer to Wiper/Washer Systems. Did you complete the repair? | -- | System OK | -- |
10 | Replace the instrument panel cluster. Refer to IP Cluster Replacement. Did you complete the repair? | -- | System OK | -- |