Relief Procedure
Tools Required
J 34730-1A Fuel Pressure
Gauge
Caution: Unless directed otherwise, the ignition and start switch must be in the OFF or LOCK position, and all electrical loads must be OFF before servicing
any electrical component. Disconnect the negative battery cable to prevent an electrical spark should a tool or equipment come in contact with an exposed electrical terminal. Failure to follow these precautions may result in personal injury and/or damage to
the vehicle or its components.
- Disconnect
the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
in Engine Electrical.
- Connect J 34730-1A
fuel pressure gauge to the fuel pressure connection. In order
to avoid spillage, wrap a shop towel around the fuel pressure connection
while connecting the fuel pressure gauge .
- Install the bleed hose into an approved container and open the
valve to bleed the system pressure. The fuel connections are now safe for
servicing.
- Drain any fuel remaining in the fuel pressure gauge into an approved
container.