Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the Instrument Cluster Diagnostic System Check? | Go to Step 2 | |
2 |
Does the low washer fluid indicator illuminate? | Go to Step 3 | Go to Step 8 |
3 |
Does the Low Washer Fluid indicator illuminate? | Go to Step 4 | Go to Step 5 |
4 |
Did you complete the repair? | System OK | -- |
5 | Test for an open in the ground circuit of the washer solvent level switch. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | System OK | Go to Step 6 |
6 | Test the signal circuit for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | System OK | Go to Step 7 |
7 | Test for a poor connection at the harness connector of the BCM. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | System OK | Go to Step 9 |
8 | Replace the instrument cluster. Refer to Instrument Cluster Replacement . Did you complete the replacement? | System OK | -- |
9 | Replace the BCM. Refer to Body Control Module Replacement in Body Control System. Important: Perform the setup procedure for the BCM. Refer to Body Control Module (BCM) Programming/RPO Configuration . Did you complete the replacement? | System OK | -- |