Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the Instrument Cluster Diagnostic System Check? | Go to Step 2 | |
2 | Disconnect the low washer fluid switch connector. Does the low washer fluid indicator turn off? | Go to Step 3 | Go to Step 5 |
3 | Inspect for poor connections at the harness connector of the low washer fluid switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 8 | Go to Step 4 |
4 | Replace the low washer fluid switch. Did you complete the replacement? | Go to Step 8 | -- |
5 | Test the signal circuit of the low washer fluid switch for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 8 | Go to Step 6 |
6 | Inspect for poor connections at the harness connector of the body control module (BCM). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 8 | Go to Step 7 |
7 | Replace the BCM. Refer to Body Control Module Replacement in Body Control System. Important: Perform the setup procedure for the BCM. Refer to Body Control Module (BCM) Programming/RPO Configuration . Did you complete the replacement? | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |