Hazard Warning Switch Replacement Pontiac
Removal Procedure
- Remove the Instrument panel (IP) accessory trim plate. Refer to
Instrument Panel Accessory Trim Plate Replacement
in Instrument
Panel, Gages and Console.
- Remove the bracket screws
from the IP accessory switch mounting plate.
- Remove the bracket.
- Use a small flat-bladed
tool in order to depress and release the hazard warning switch retainers.
Press the switch out with your thumb.
- Remove the hazard warning
switch.
Installation Procedure
- Position the hazard warning
switch to the bracket.
- Install the switch to
the bracket by pressing into place until fully seated.
- Position the bracket to
the IP accessory trim plate.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the mounting
plate bracket screws to the IP accessory switch.
Tighten
Tighten the screws to 3 N·m (27 lb in).
- Install the IP accessory trim plate. Refer to
Instrument Panel Accessory Trim Plate Replacement
in Instrument Panel, Gages
and Console.
Hazard Warning Switch Replacement Oldsmobile
Removal Procedure
- Remove
the hazard warning switch bezel from the instrument panel (I/P) using a small-flat
bladed tool to release the retainers.
- Remove
the I/P center air outlet. Refer to
Instrument Panel Center Air Outlet Replacement
in Heating, Ventilation and Air Conditioning.
- Remove the I/P cluster. Refer to
Instrument Cluster Replacement
in Instrument Panel, Gages and Console.
- Remove the left side bolt from the hazard warning switch through the instrument
panel cluster pocket.
- Remove
the right side and center lower bolts from the hazard warning switch through the center
air outlet opening.
- Reposition
the hazard warning switch to the center air outlet opening.
- Disconnect
the electrical connectors from the hazard warning switch.
- Remove the hazard warning switch from the I/P.
Installation Procedure
- Connect
the electrical connector to the hazard warning switch.
- Position
the hazard warning switch to the mounting points in the I/P.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the left side bolt to the hazard warning switch through the I/P cluster
pocket.
Tighten
Tighten the bolt to 3 N·m (27 lb in).
- Install
the right side and center lower bolts to the hazard warning switch through the center
air outlet opening.
Tighten
Tighten the bolt to 3 N·m (27 lb in).
- Install the I/P cluster. Refer to
Instrument Cluster Replacement
in Instrument Panel, Gages and Console.
- Install the I/P center air outlet. Refer to
Instrument Panel Center Air Outlet Replacement
in Heating, Ventilation
and Air Conditioning.
- Install
the hazard warning switch bezel to the I/P. Press the bezel into place until fully
seated.