Instrument Panel Insulator Panel Replacement - Left Side Outboard
Removal Procedure
- Remove the retainer from the outboard instrument panel insulator.
- Disengage the outboard insulator tab from the inboard insulator.
- Pull the insulator from the stud.
- Remove the insulator.
Installation Procedure
- Install the insulator to the stud.
- Attach the outboard insulator tab to the inboard insulator.
- Install the retainer.
Instrument Panel Insulator Panel Replacement - Left Side Inboard
Removal Procedure
- Remove the outboard instrument panel (I/P) insulator. Refer to
Instrument Panel Insulator Panel Replacement - Left Side
.
- Remove the inboard I/P insulator screws.
- Slide the I/P insulator from the HVAC module. Disconnect the defroster duct from the I/P insulator.
- Remove the inboard I/P insulator.
Installation Procedure
- Position the inboard I/P insulator to the lower I/P.
- Connect the defroster duct to the I/P insulator. Slide the I/P insulator to the HVAC module.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
Important: Place the shift interlock cable in the notch when you install the screw to the HVAC module.
- Install the I/P insulator screws.
Tighten
Tighten the screws to 2 N·m (18 lb in).
- Install the left outboard I/P insulator. Refer to
Instrument Panel Insulator Panel Replacement - Left Side
.