Removal Procedure
- Remove the I/P trim pad. Refer to
Instrument Panel Trim Pad Replacement
in Instrument Panel, Gages, and Console.
- Remove the DRL sensor from the defroster duct by turning 1/4 of a turn.
- Remove the two push on retainers holding the defroster duct to the HVAC module assembly.
- Remove the defroster duct retainers from the air distribution duct.
- Remove the defroster duct.
Installation Procedure
- Align the defroster duct to the air distribution duct and the HVAC module assembly.
- Install the retainers on the defroster duct to the air distribution duct.
- Install the two push on retainers holding the defroster duct to the HVAC module assembly.
- Install the DRL sensor to the defroster duct.
Turn 1/4 turn to lock in position.
- Install the I/P trim pad. Refer to
Instrument Panel Trim Pad Replacement
in Instrument Panel, Gages, and Console.