Removal Procedure
Caution: Refer to SIR Caution in the Preface section.
Caution: Refer to SIR Inflator Module Handling and Storage Caution in the Preface section.
- Disable the SIR system. Refer to
SIR Disabling and Enabling
.
- Remove the instrument panel (I/P) compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gages, and Console.
- Remove the connector position assurance (CPA) from the inflatable restraint I/P module yellow 2-way connector (2).
- Disconnect the inflatable restraint I/P module yellow 2-way connector (2).
- Disconnect the module harness from the from the fuse block bracket.
- Remove the inflatable restraint I/P module screws (3).
- Remove the inflatable restraint I/P module (1).
Installation Procedure
- Make sure the module harness is routed correctly. Install the inflatable restraint instrument panel (I/P) module (1).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the screws (3) that secure the inflatable restraint I/P module.
Tighten
Tighten the screws to 10 N·m (89 lb in).
- Connect the module harness to the fuse block bracket.
- Connect the inflatable restraint I/P module yellow 2-way connector (2).
- Install the CPA to the inflatable restraint I/P module yellow 2-way connector (2).
- Install the I/P compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gages, and Console.
- Enable the SIR system. Refer to
SIR Disabling and Enabling
.