Removal Procedure
- If you are removing the
right conduit, remove the right instrument panel insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in
Instrument Panel, Gages and Console.
- Remove the door rubber conduit from where it attaches at the windshield
pillar.
- Disconnect the body harness
electrical connector from the front door wiring harness.
- Remove the conduit from the front door.
- Remove the front door wiring harness out from the rubber conduit.
Installation Procedure
- Install the wiring harness
to the front door through the rubber conduit.
- Install the rubber conduit to the front door.
- Install the rubber conduit
to the windshield pillar.
- Connect the front door wiring harness electrical connector to
the body harness.
- Install the right instrument panel insulator if required. Refer
to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel, Gages and Console.