J 38758 Parasitic Draw Test Switch
Notice: Do not turn the parasitic draw test switch to the OFF position with the engine running. Damage will occur to the vehicle's electrical system.
Notice: The test switch must be in the ON position when removing the fuses in order to maintain continuity in the electrical system. This avoids damaging the digital multimeter due to accidental overloading, such as a door being opened to change a fuse.
Important: The switch knob (1) on the J 38758 is marked ON and OFF. When the switch knob is in the ON position, the circuit is closed and electrical current will pass through the switch. When the switch knob is in the OFF position, the circuit is open and electrical current will not pass through the switch.
Caution: Refer to Battery Disconnect Caution in the Preface section.
• | When there is a current reading of 2 A or less, turn the J 38758 knob to the ON position. The electrical current will now pass through the switch. |
• | Then, switch the digital multimeter down to the 2 A scale for a more accurate reading when the J 38758 knob is turned OFF. |
17.1. | Divide the reserve capacity by 4. |
17.2. | Compare this to the multimeter milliampere reading taken in the previous step. |
The parasitic current drain should not exceed this number.
Example: If a battery has a reserve capacity of 100 minutes, the current drain should not exceed 25 mA.
Important: You must prevent interruption of power to the OnStar module as current GPS function may not continue, in which case the GPS location cycle may not occur. Refer to OnStar Description and Operation in Cellular Communication. |
17.3. | If the measured parasitic load is not excessive, continue testing enough to verify the OnStar normal cycle from Sleep Mode to Low Power Mode. The cycle is evident as the ammeter reading will temporarily increase between 80 and 240 mA and varies. The cycle, which lasts about 45 seconds, this should occur at 9 or 10 minute intervals. If no cycle is observed move the vehicle to an open outside area and retest. |
Notice: The test switch must be in the ON position when removing the fuses in order to maintain continuity in the electrical system. This avoids damaging the digital multimeter due to accidental overloading, such as a door being opened to change a fuse.
If it has been determined that the OnStar system is the source of parasitic load, refer to OnStar Battery Consumption Test in Cellular Communication.
Tighten
Tighten the negative battery cable terminal bolt
to 17 N·m (13 lb ft).