Removal Procedure
- Remove the case side cover. Refer to
Control Valve Body Cover Replacement .
- Disconnect the transaxle wiring harness.
- Using a small screwdriver or pick, remove the pressure control solenoid valve retainer (314E) from the control valve body (301).
- Remove the pressure control solenoid (322).
- Remove the O-ring seals (307, 316) from the PC solenoid valve (322) ONLY if they are damaged.
Installation Procedure
- Install new O-ring seals (307, 316) onto the pressure control (PC) solenoid valve (322), if they had been removed.
- Install the pressure control solenoid (322).
- Hold the PC solenoid valve (322) in the control valve body (301). Install the pressure control solenoid valve retainer (314E) into the control valve body (301).
- Connect the transaxle wiring harness.
- Install the case side cover. Refer to
Control Valve Body Cover Replacement .
Important: It is recommended that transmission adaptive pressure (TAP) information be reset.
Resetting the TAP values using a scan tool will erase all learned values in all cells. As a result, The ECM, PCM or TCM will
need to relearn TAP values. Transmission performance may be affected as new TAP values are learned.
- Reset the TAP values. Refer to
Adapt Function.