Table 1: | DIM |
Table 2: | IPM |
Table 3: | PCM |
Scan Tool Output Control | Additional Menu Selection(s) | Description |
---|---|---|
A/C Orifice Relay | -- | The scan tool displays Commanded State: None, Off or On. This function allows you to command the A/C orifice solenoid to its maximum (On) or minimum (Off) diameters. |
Scan Tool Output Control | Additional Menu Selection(s) | Description |
---|---|---|
Afterblow | Set Options | Allows the blower motor to run after the ignition is turned OFF. |
Air Inlet Door Position | HVAC Motors | The scan tool displays Outside or Recirc selections. The selection drives the actuator to its min or max stops. |
Blower Motor | Miscellaneous | The scan tool displays Commanded State: None, Off or On. This function allows you to command the blower motor to its maximum (100%) or minimum (0%) speeds. |
HTR/DEF/AC Door Position | HVAC Motors | The scan tool displays Defrost or Panel selections. The selection drives the actuator to its min or max stops. |
Instant OAT Update | Miscellaneous | The scan tool displays Commanded State: None, Off or On. Updates the IPM outside air temperature input to the current raw value. |
Left Temp Door Position | HVAC Motors | The scan tool displays Hot or Cold selections. The selection drives the actuator to its min or max stops. |
Recalibrate All Motors | Miscellaneous | The scan tool displays Commanded State: None or On. This function commands the actuators to drive to the stops fully opened and fully closed and relearn these endpoints. |
Relearn Control Panel Type | Miscellaneous | The scan tool displays Commanded State: None or On. This function has the IPM relearn a new heater and A/C control. |
Right Temp Door Position | HVAC Motors | The scan tool displays Hot or Cold selections. The selection drives the actuator to its min or max stops. |
Temperature Offset | Set Options | Allows for variation between driver set temperature and target (desired) system discharge temperature. |
Scan Tool Output Control | Additional Menu Selection(s) | Description |
---|---|---|
A/C Relay | -- | The scan tool displays ON or OFF selections. This command allows you to turn the A/C relay ON or OFF. |
A/C Relay Command | -- | The scan tool displays ON or OFF selections. ON is displayed when the PCM has energized the A/C clutch relay. |