The Mitsubishi scroll type A/C compressor carries an internal thermal cut off switch. The thermal cut off switch normal operation is to open and disable the compressor under extreme load and temperatures above 155°C (311°F). The internal thermal cut off switch is non-serviceable.
Step | Action | Values | Yes | No | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Definition: The temperature cannot be adjusted, or the cooling is insufficient during A/C operation. | ||||||||||||||||||||||||
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | |||||||||||||||||||||
2 |
Does the scan tool display any DTCs? | -- | Go to Step 3 | |||||||||||||||||||||
3 |
Does the A/C orifice solenoid turn ON and OFF with each command? | -- | Go to Step 4 | |||||||||||||||||||||
4 | Place the blower motor switch in each speed position. Does the blower motor operate in any of the speed positions? | -- | Go to Step 5 | Go to Blower Motor Inoperative | ||||||||||||||||||||
5 | Does the blower motor operate in each speed position? | -- | Go to Step 6 | Go to Blower Motor Malfunction | ||||||||||||||||||||
6 |
Important:: Ambient air temperature must be above 3°C (38°F).
Does the A/C compressor clutch engage? | -- | Go to Step 7 | |||||||||||||||||||||
7 | Perform the A/C system performance test. Refer to Air Conditioning (A/C) System Performance Test in Heating, Ventilation, and Air Conditioning. Did you find and correct the condition? | -- | Go to Step 23 | Go to Step 8 | ||||||||||||||||||||
8 | Inspect the temperature sensors for proper installation. Refer to the following procedures: Did you find and correct the condition? | -- | Go to Step 23 | Go to Step 9 | ||||||||||||||||||||
9 |
Does the paper stay in place? | -- | Go to Step 10 | Go to Step 14 | ||||||||||||||||||||
10 |
Does the scan tool indicate that the Right and Left Solar Sensor data parameters are greater than the specified value? | 224 Counts | Go to Step 11 | Go to Step 18 | ||||||||||||||||||||
11 |
Do the counts change similarly and correspond to the proper side of the sunload sensor assembly? | -- | Go to Step 12 | Go to Step 18 | ||||||||||||||||||||
12 |
Does the scan tool indicate sensor temperatures near the thermometer temperatures within the specified range? | +3 to -3°C (+5 to -5°F) | Go to Step 13 | Go to Step 15 | ||||||||||||||||||||
13 | Does the customer need to change the set temperature frequently to maintain comfort? | -- | Go to Air Conditioning (A/C) System Does Not Maintain Set Temperature | Go to Step 17 | ||||||||||||||||||||
14 | Inspect for a blocked or disconnected aspiration hose. Did you find and correct the condition? | -- | Go to Step 23 | -- | ||||||||||||||||||||
15 | Inspect for poor connections at the harness connector of the suspect temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 23 | Go to Step 16 | ||||||||||||||||||||
16 | Test the suspect temperature sensor resistance. Refer to Sensor Resistance Table . Does the resistance measure near the Sensor Resistance Table value? | -- | Go to Step 19 | Go to Step 20 | ||||||||||||||||||||
17 |
Did you complete the repair? | -- | Go to Step 23 | -- | ||||||||||||||||||||
18 | Inspect for poor connections at the harness connector of the sunload sensor assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 23 | Go to Step 21 | ||||||||||||||||||||
19 | Inspect for poor connections at the harness connector of the instrument panel integration module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 23 | Go to Step 22 | ||||||||||||||||||||
20 | Replace the suspect air temperature sensor. Refer to the following procedures: Did you complete the replacement? | -- | Go to Step 23 | -- | ||||||||||||||||||||
21 | Replace the sunload sensor assembly. Refer to Sun Load Sensor Assembly Replacement in Instrument Panel, Gauges, and Console. Did you complete the replacement? | -- | Go to Step 23 | -- | ||||||||||||||||||||
22 |
Important: : Perform the Recalibration procedure for the instrument panel integration module. Replace the instrument panel integration module. Refer to Instrument Panel Module Replacement in Body Control System. Did you complete the replacement? | -- | Go to Step 23 | -- | ||||||||||||||||||||
23 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |