Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Interior Lights Schematics | |||
1 | Did you perform the Lighting Systems Diagnostic System Check? | Go to Step 2 | |
2 |
Did the vanity mirror lamps operate properly? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Do the courtesy lamps operate properly? | Go to Step 4 | |
4 |
Does the test lamp illuminate? | Go to Step 6 | Go to Step 5 |
5 | Test the courtesy lamp supply voltage circuit for a high resistance or open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 9 | Go to Step 7 |
6 | Inspect for poor connections at the inoperative vanity mirror lamp bulb. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 9 | Go to Step 8 |
7 | Repair the high resistance or an open in the ground circuit of the inoperative vanity mirror lamp bulb. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 9 | -- |
8 | Replace the inoperative vanity mirror lamp bulb. Did you complete the replacement? | Go to Step 9 | -- |
9 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |