Step | Action | Yes | No |
---|---|---|---|
Schematic References: Door Lock/Indicator Schematics and Door Control Module Schematics | |||
1 | Did you perform the Door Systems Diagnostic System Check? | Go to Step 2 | |
2 |
Does the scan tool display Off for all four doors? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the scan tool display Off? | Go to Step 5 | Go to Step 4 |
4 | Test the signal circuit of the suspect door ajar switch for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 9 | Go to Step 6 |
5 | Inspect for poor connections at the harness connector of the suspect door ajar switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 9 | Go to Step 7 |
6 | Inspect for poor connections at the harness connector of the suspect door module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 9 | Go to Step 8 |
7 | Replace the suspect door lock actuator. Refer to Front Side Door Latch Replacement or Rear Side Door Latch Replacement in Doors. Did you complete the replacement? | Go to Step 9 | -- |
8 | Replace the suspect door module. Refer to Door Control Module Replacement in Doors. Did you complete the replacement? | Go to Step 9 | -- |
9 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |