Perform the following procedures while wiggling the harness from side to side. Continue this at convenient points (about 6 inches apart) while watching the test equipment.
If the fault is not identified, perform the procedure below using the MIN MAX feature on the DMM. This feature allows you to manipulate the circuit without having to watch the DMM. The DMM will generate an audible tone when a change is detected.
Important: The J 39200 must be used in order to perform the following procedure since the J 39200 can monitor current, resistance or voltage while recording the minimum (MIN), and maximum (MAX) values measured.
Important: The 100 ms RECORD mode is the length of time an input must stay at a new value in order to record the full change.
• | If the variation between the recorded MIN and MAX voltage values is 1 volt or greater an intermittent open or high resistance condition exists. Repair the condition as necessary. |
• | If the variation between the recorded MIN and MAX voltage values is less than 1 volt an intermittent open or high resistance condition does not exist. |