- Install the HVAC module.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the HVAC module nuts to the cowl (1-5). Refer to the illustration
for the HVAC module fastener torque sequence.
Tighten
Tighten the nuts to 9 N·m (80 lb in).
- Connect the blower control module (1)
connection.
- Connect the I/P to HVAC module connector (2).
- Install the defroster duct and the module
mounting screws (1, 2).
Tighten
Tighten the screws to 1.4 N·m (12 lb in).
- Install the defroster duct mounting nut (3) to the front of dash.
Tighten
Tighten the nut to 9 N·m (80 lb in).
- Install the air distributor duct and screws.
Tighten
Tighten the screws to 1.4 N·m (12 lb in).
- Install the lower IP support bracket.
- Install the IP assembly. Refer to
Instrument Panel Carrier Replacement
in Instrument Panel, Gages and Console.
- Install the heater hoses (1, 2) to the heater core.
- Using the J 38185
Reposition
the hose clamps into their original position.
- Connect the evaporator hose connection
to the evaporator.
- Install the evaporator hose nut.
Tighten
Tighten the nut to 20 N·m (15 lb ft).
- Recharge the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Leak test the fittings of the component using the J 39400-A
.
- Refill the engine coolant. Refer to
Cooling System Draining and Filling
in Engine Cooling.