Step | Action | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|
DEFINITION: Noise originating from the blower motor. | |||||||||
1 | Were you sent here from the HVAC Symptoms? | Go to Step 2 | |||||||
2 |
Did you hear a noise during the blower operation? | Go to Step 3 | Go to Step 10 | ||||||
3 | Does the noise vary with the blower speed? | Go to Step 4 | Go to Step 10 | ||||||
4 | Inspect for excessive vibration at each blower motor speed by feeling the blower case. Is excess vibration present? | Go to Step 5 | Go to Step 6 | ||||||
5 |
Important: Inspect the blower motor impeller cavity through the access hole under the air inlet grille panel. Examine the blower motor cavity for deposits of foreign material. Did you find foreign material? | Go to Step 7 | Go to Step 6 | ||||||
6 |
Did you find any of these conditions? | Go to Step 8 | Go to Step 10 | ||||||
7 | Remove the foreign material. Is the action complete? | Go to Step 10 | -- | ||||||
8 | Replace the blower motor. Refer to Blower Motor Replacement . Is the replacement complete? | Go to Step 10 | -- | ||||||
9 | Install the blower motor. Refer to Blower Motor Replacement . Is the action complete? | Go to Step 10 | -- | ||||||
10 | Operate the system in order to verify the repair. Does the system operate correctly? | System OK | Go to Step 2 |