Removal Procedure
- Remove the IP retainer. Refer to
Instrument Panel Retainer Replacement
in Instrument Panel, Gages and Console.
- Remove the dash integration module (DIM) from the bracket.
- Remove the rear 2 DIM module bracket screws.
- Reposition the DIM module bracket to gain access to the recirculation
actuator.
- Disconnect the electrical connector from the recirculation actuator.
- Remove the recirculation actuator retaining screws.
- Remove the recirculation actuator.
Installation Procedure
- Install the recirculation actuator.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the recirculation actuator retaining screws.
Tighten
Tighten the screws to 1.4 N·m (12 lb in).
- Connect the electrical connector to the recirculation actuator.
- Position the DIM module bracket to its original
position.
- Install the rear 2 DIM module bracket retaining screws.
Tighten
Tighten the fasteners to 1.4 N·m (12 lb in).
- Install the DIM module into the bracket.
- Install the IP retainer. Refer to
Instrument Panel Retainer Replacement
in Instrument Panel, Gages
and Console.
- Recalibrate the actuators. Refer to
Actuator Recalibration
.