Removal Procedure
- Ensure that the window
is fully closed.
- Remove the door trim panel. Refer to
Rear Side Door Trim Panel Replacement
.
- Remove the door module. Refer to
Door Control Module Replacement
.
- Remove the water deflector. Refer to
Rear Side Door Water Deflector Replacement
.
- Loosen the lower fastener (3).
- Remove the upper fastener (1).
- Rotate the top of the front window channel forward.
- Lift upward on the front window channel in order to disengage
the lower fastener from the keyhole slot.
- Remove the front window channel from the door.
Installation Procedure
- Install the front window
channel into the door, top end first.
- Insert the lower fastener (3) into the keyhole slot.
- Rotate the top of the front window channel rearward and align
on the lower edge of the window.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the top fastener.
Tighten
Tighten the front window channel fasteners to 9 N·m (80 lb in).
- Install the water deflector. Refer to
Rear Side Door Water Deflector Replacement
.
- Install the door module. Refer to
Door Control Module Replacement
.
- Install the door trim panel. Refer to
Rear Side Door Trim Panel Replacement
.