Temperature | Resistance | Signal | |||
---|---|---|---|---|---|
°F | °C | Minimum ohms | Normal ohms | Maximum ohms | Volts |
-40 | -40 | 90636 | 100707 | 110778 | 5 |
-22 | -30 | 47416 | 52684 | 57952 | 4.78 |
-4 | -20 | 25809 | 2677 | 31545 | 4.34 |
14 | -10 | 14558 | 16176 | 17784 | 3.89 |
32 | 0 | 8481 | 9423 | 10365 | 3.45 |
50 | 10 | 5104 | 5671 | 6238 | 3.01 |
68 | 20 | 3164 | 3515 | 3867 | 2.56 |
86 | 30 | 2013 | 2237 | 2461 | 1.8 |
104 | 40 | 1313 | 1459 | 1605 | 1.1 |
122 | 50 | 876 | 973 | 1070 | 3.25 |
140 | 60 | 600 | 667 | 734 | 2.88 |
158 | 70 | 420 | 467 | 514 | 2.56 |
176 | 80 | 299 | 332 | 365 | 2.24 |
194 | 90 | 217 | 241 | 265 | 1.7 |
212 | 100 | 159 | 177 | 195 | 1.42 |
230 | 110 | 119 | 132 | 145 | 1.15 |
248 | 120 | 89.9 | 99.9 | 109.9 | 0.87 |
266 | 130 | 69.1 | 76.8 | 84.5 | 0.6 |
284 | 140 | 53.8 | 59.8 | 65.8 | 0.32 |
302 | 150 | 42.5 | 47.2 | 51.9 | 0 |
A shunt in the Controller becomes active as the temperature increases beyond 50°C (122°F). As the temperature decreases, the internal shunt deactivates at 40°C (104°F). |