The transfer case encoder motor is a permanent magnet DC motor and gear reduction assembly. The encoder motor is controlled with a pulse width modulated (PWM) circuit within the transfer case shift control module. This circuit consists of a power supply relay (Motor Feed A) circuit that supplies voltage to the motor. The Motor Control B circuit is a PWM driver that varies the duty cycle to control the amount of current through the motor to ground.
This DTC detects a short to power on the Motor Feed A circuit or the Motor Control B circuit.
• | The system will test the motor circuits by checking for unwanted voltage. |
• | The system supplies voltage on the Motor A circuit and reads the voltage back on the Motor B circuit. |
• | The transfer case shift control module senses a high voltage return on the Motor Feed A circuit or the Motor Control B circuit when a low voltage is expected. |
• | If the system detects a problem with the circuits, the DTC is logged. |
• | All clutch activation (slip control) will be disabled. |
• | The SERVICE indicator (AWD/4WD) lamp will be latched on for the remainder of the current ignition cycle. |
• | Current DTC |
The transfer case shift control module will clear the DTC if the condition for setting the DTC no longer exists. |
• | A history DTC will clear after 100 consecutive ignition cycles without a fault present. |
• | History DTCs can be cleared using a scan tool. |
The numbers below refer to the step numbers on the diagnostic table.
Tests the motor circuit for a current malfunction.
Tests Motor Feed A for an open or short to voltage.
Tests Motor Control B for an open or short to voltage.
Tests for continuity across the motor windings.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Transfer Case Diagnostic System Check performed? | -- | Go to Step 2 | Go to Diagnostic System Check |
Does the Encoder Motor turn ON and OFF? | -- | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 | |
Was the condition found and corrected? | -- | Go to Step 8 | Go to Step 4 | |
Test Motor Control B for an open or short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Was the condition found and corrected? | -- | Go to Step 8 | Go to Step 5 | |
Test for continuity across the motor circuit. Was there continuity? | -- | Go to Step 7 | Go to Step 6 | |
6 | Replace the encoder motor. Refer to Motor/Encoder Replacement . Is the repair complete? | -- | Go to Step 8 | -- |
7 | Replace the transfer case shift control module. Refer to Transfer Case Shift Control Module Replacement . Is the repair complete? | -- | Go to Step 8 | -- |
8 |
Does the DTC reset? | -- | Go to Step 2 | System OK |