GM Service Manual Online
For 1990-2009 cars only

Tools Required

GE-47676 Mode Actuator Removal Tool

Removal Procedure

  1. Remove the left floor duct. Refer to Floor Air Outlet Duct Replacement - Left Side .
  2. Important: The service actuator is positioned in the bi-level mode. Place the mode door in the middle of the door's travel.

  3. Disconnect the mode actuator electrical connector.
  4. Remove the mode actuator mounting screws.
  5. Using GE-47676 remove the mode actuator.

Installation Procedure

  1. Install the mode actuator.
  2. Notice: Refer to Fastener Notice in the Preface section.

  3. Install the mode actuator mounting screws.
  4. Tighten
    Tighten the screws to 1.9 N·m (17 lb in).

  5. Connect the mode actuator electrical connector.
  6. Install the left floor duct. Refer to Floor Air Outlet Duct Replacement - Left Side .