Removal Procedure
- Remove the I/P carrier. Refer to
Instrument Panel Carrier Replacement
in Instrument Panel, Gages and Console.
- Remove the air temperature actuator-left (1) retaining screws.
- Disconnect the air temperature actuator-left electrical connector.
- Remove the air temperature actuator-left.
Installation Procedure
- Install the air temperature actuator-left (1).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the air temperature actuator-left retaining screws.
Tighten
Tighten the screws to 1.9 N·m (17 lb in).
- Connect the air temperature actuator-left electrical connector.
- Install the I/P carrier. Refer to
Instrument Panel Carrier Replacement
in Instrument Panel, Gages, and Console.
- Recalibrate the air temperature actuator on vehicles equiped
with automatic climate control (C68). Refer to
Actuator Recalibration
.