When the ignition switch is first turned to the RUN position, the IPC/BFC Fuse applies battery voltage to the AIR BAG warning lamp that is connected to INFLATABLE RESTRAINT INDICATOR, terminal 7. The AIR BAG Fuse applies battery voltage to the IGNITION 1 input, terminal 10. The inflatable restraint Sensing and Diagnostic Module (SDM) responds by flashing the AIR BAG warning lamp seven times. If IGNITION 1 is outside of the normal operating voltage range (8.2 volts -17.1 volts), the AIR BAG warning lamp will come ON solid with no DTCs set.
In order to disable the shorting bar from terminal 6 to terminal 7 inside the inflatable restraint Sensing and Diagnostic Module (SDM) harness connector, the following two conditions must be met:
• | The SDM harness connector must be properly connected to the SDM. |
• | The Connector Position Assurance (CPA) must be properly installed in the SDM harness connector. |
When measurements are requested in this table, use the J 39200 DMM with the correct terminal adapter from the J 35616 Connector Test Adapter Kit. When an inspection for proper connection is requested, refer to Testing for Electrical Intermittents in Wiring Systems. When a wire, connector or terminal repair is requested, use the J-38125 Terminal Repair Kit and refer to Wiring Repairs in Wiring Systems.
The numbers below refer to the step numbers on the diagnostic table:
This test checks for sufficient IGNITION voltage applied to the SDM.
This test checks for excessive IGNITION voltage applied to the SDM.
This test checks for a properly installed CPA.
This test determines if the SDM is turning on the AIR BAG warning lamp.
This test checks for a damaged shorting bar.
This test determines whether the malfunction is a short to ground in CKT 358.
This test checks for a short between CKT 358 and CKT 1751.
An open AIR BAG Fuse would cause the AIR BAG warning lamp to come on steady.
This test checks whether a short to ground caused the AIR BAG Fuse to open.
This test determines whether the short to ground is due to a short in the wiring or internal to the SDM.
This test checks for a disconnected SDM.
This test checks for an open in the IGNITION circuit.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the SIR Diagnostic System Check performed? | -- | ||
Is IGNITION more than the specified value? | 8.2 V | |||
Is IGNITION more than the specified value? | 17.1 V | Go to Charging System Check | ||
Is the CPA properly installed? | -- | |||
5 | Properly install the CPA. Are the repairs complete? | -- | -- | |
Does the AIR BAG warning lamp come ON steady? | -- | Go to Integrity Check | ||
Is the shorting bar damaged or corroded? | -- | |||
8 | Replace the SDM harness connector. Refer to Wiring Repair Are the repairs complete? | -- | -- | |
Is the resistance reading less than the specified value? | OL | |||
Is the resistance reading less than the specified value? | OL | |||
11 | Repair a short-to-ground condition in CKT 358. Are the repairs complete? | -- | -- | |
12 |
Are the repairs complete? | -- | -- | |
13 | Service the instrument cluster. Refer to Instrument Cluster Replacement in Instrument Panel, Gauges and Console. Are the repairs complete? | -- | -- | |
Is the AIR BAG Fuse good? | -- | |||
Is the AIR BAG Fuse good? | -- | |||
Is the AIR BAG Fuse good? | -- | |||
17 |
Are the repairs complete? | -- | -- | |
18 |
Are the repairs complete? | -- | -- | |
19 | Install the AIR BAG Fuse. Are the repairs complete? | -- | -- | |
Inspect the SDM harness connector. Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement . Is the connector secure? | -- | |||
21 |
Are the repairs complete? | -- | -- | |
22 |
Is the SDM harness connector terminal damaged or corroded? | -- | ||
23 | Replace the SDM harness connector. Refer to Wiring Repair . Are the repairs complete? | -- | -- | |
24 | Inspect the SDM terminals for damage or corrosion. Are any terminals damaged or corroded? | -- | ||
25 | Replace the inflatable restraint Sensing and Diagnostic Module (SDM). Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement . Are the repairs complete? | -- | -- | |
Measure the resistance from the SDM harness connector terminal 10 to each terminal of the AIR BAG Fuse fuseholder. Is either resistance reading within the specified values? | 0-5 ohms | Go to Integrity Check | ||
27 | Repair an open condition in CKT 1139. Are the repairs complete? | -- | -- | |
28 | Reconnect all the SIR system components, make sure all the components are properly mounted. Have all the SIR components been reconnected and properly mounted? | -- | -- |