Tools Required
- Inspect the modulator components for the
follow conditions:
• | A damaged modulator valve (34) |
• | A damaged modulator assembly (32) |
• | A damaged modulator O-ring seal (33) |
• | A damaged modulator retainer (31) |
- Install J 23738-A
or
equivalent onto the vacuum pipe nipple of the modulator assembly.
- Apply 15 kPa of vacuum to the modulator assembly (32) under
the following criteria:
• | Hold the vacuum for 30 seconds |
• | Confirm that the plunger retracts into the modulator assembly |
- Remove J 23738-A
from
the modulator assembly.
- Use a modulator
assembly that is known to be good.
- Install J 36619
between
the good modulator and the modulator to be checked.
- Push the modulators towards each other.
- Note the indicator on J 36619
:
• | If the indicator line (1) is visible, the modulator is OK |
• | If the indicator line moves out of view, replace the modulator |