Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Diagnosis of the circuits in the automatic transmission (A/T) wiring harness assembly related to the automatic transmission fluid pressure (TFP) manual valve position switch is covered in the diagnostic resistance check for that component. Refer to Transmission Fluid Pressure Manual Valve Position Switch Resistance Check . | ||||||||||
1 |
Is the resistance within the specified values? | 19-24 ohms at 20°C (68°F) 24-31 ohms at 88°C (190°F) | ||||||||
2 |
Is the resistance within the specified values? | 19-24 ohms at 20°C (68°F) 24-31 ohms at 88°C (190°F) | ||||||||
3 | Measure the resistance between terminals B and E (2-3 SS valve). Is the resistance within the specified values? | 19-24 ohms at 20°C (68°F) 24-31 ohms at 88°C (190°F) | ||||||||
4 |
Is the resistance within the specified values? | 19-24 ohms at 20°C (68°F) 24-31 ohms at 88°C (190°F) | ||||||||
5 | Measure the resistance between terminals T and E (TCC PWM solenoid valve). Is the resistance within the specified values? | 10-12 ohms at 20°C (68°F) 13-15 ohms at 88°C (190°F) | ||||||||
6 |
Is the resistance within the specified values? | 10-12 ohms at 20°C (68°F) 13-15 ohms at 88°C (190°F) | ||||||||
7 | Measure the resistance between terminals C and D (PC solenoid valve). Is the resistance within the specified values? | 3-5 ohms at 20°C (68°F) 5-6 ohms at 88°C (190°F) | ||||||||
8 |
Is the resistance within the specified values? | 3-5 ohms at 20°C (68°F) 5-6 ohms at 88°C (190°F) | ||||||||
9 | Measure the resistance between terminals S and V (A/T ISS). Is the resistance within the specified values? | 893-1127 ohms at 20°C (68°F) 1132-1428 ohms at 88°C (190°F) | ||||||||
10 |
Is the resistance within the specified values? | 893-1127 ohms at 20°C (68°F) 1132-1428 ohms at 88°C (190°F) | ||||||||
11 | Measure the resistance between terminals M and L (TFT sensor). Is the resistance within the specified values? | 3164-3867 ohms at 20°C (68°F) 225-285 ohms at 88°C (190°F) | ||||||||
12 |
Is the resistance within the specified values? | 3164-3867 ohms at 20°C (68°F) 225-285 ohms at 88°C (190°F) | ||||||||
13 | Using the J 39200 DMM and the J 35616-A connector test adapter kit, measure the resistance of the A/T wiring harness assembly from pins A, B, C, D, E, L, M, S, T and V of the transmission 20-way connector to the transmission case. Is the resistance more than shown? | 250 K ohms | System OK | |||||||
14 | Inspect for high resistance:
Was the condition found and corrected? | -- | -- | |||||||
15 | Replace the Automatic Transmission Wiring Harness Assembly. Is the replacement complete? | -- | -- | |||||||
16 | Replace the component. Is the replacement complete? | -- | -- |