The ignition switch supplies Ignition 1 voltage to the inflatable restraint sensing and diagnostic module (SDM) at terminal 10 using the AIR BAG Fuse. The ignition switch also supplies Ignition 1 voltage to the AIR BAG warning lamp using the CLUSTER Fuse. The AIR BAG warning lamp is connected to the INFLATABLE RESTRAINT INDICATOR at terminal 7 of the SDM. When the ignition switch is first turned to the RUN position, the SDM responds by flashing the AIR BAG warning lamp seven times. If IGNITION 1 is outside of the normal operating voltage range (8.2 volts-17.1 volts), the AIR BAG warning lamp will come ON solid with no DTC's set.
In order to disable the shorting bar from terminal 6 to terminal 7 inside the inflatable restraint sensing and diagnostic module (SDM) wiring harness connector, the following two conditions must be met:
• | The SDM wiring harness connector must be properly connected to the SDM. |
• | The connector position assurance (CPA) must be properly installed in the SDM wiring harness connector. |
When measurements are requested in this table, use the J 39200 DMM with the correct terminal adapter from the J 35616 Connector Test Adapter Kit. When an inspection for proper connection is requested, refer to Testing for Electrical Intermittents in Wiring Systems. When a wire, connector or terminal repair is requested, use the J-38125 Terminal Repair Kit and refer to Wiring Repairs in Wiring Systems.
The numbers below refer to the step numbers on the diagnostic table:
This step checks to see if sufficient IGNITION voltage is applied to the SDM.
This step checks to see if excessive IGNITION voltage is applied to the SDM.
This step checks to see if the connector position assurance (CPA) is properly installed.
This step determines if the SDM is turning on the AIR BAG warning lamp or if there is a malfunctioning SDM.
This step checks to see if the shorting bar is damaged.
This step checks to see if there is a short to ground in CKT 358.
This step determines if there is a short between CKT 358 and CKT 1751 or if there is a short to ground in CKT 358.
This step checks to see if Fuse 21 is OK. An open Fuse 21 would cause the AIR BAG warning lamp to come on steady.
This step checks to see if a short to ground caused Fuse 21 to open.
This step checks to see if there is a short to ground in CKT 1139.
This step checks to see if the SDM wiring harness connector properly secures to the SDM.
This step checks to see if there is an open in CKT 1139.
This step determines if there is an open or a high resistance in the B+ feed circuit to the input side of Fuse 21 or if there is a malfunctioning SDM.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the SIR Diagnostic System Check performed? | -- | ||
Is IGNITION more than the specified value? | 8.2 V | |||
Is IGNITION more than the specified value? | 17.1 V | Go to Battery Is Undercharged or Overcharged in Engine Electrical | ||
Is the CPA properly installed? | -- | |||
5 | Properly install the CPA. Is the repair complete? | -- | -- | |
Does the AIR BAG warning lamp come ON steady? | -- | |||
Is the shorting bar damaged or corroded? | -- | |||
8 | Replace the SDM wiring harness connector. Refer to Wiring Repair . Is the repair complete? | -- | -- | |
Is the measured resistance less than the specified value? | OL | |||
Is the measured resistance less than the specified value? | OL | |||
11 |
Is the repair complete? | -- | -- | |
12 |
Is the repair complete? | -- | -- | |
13 | Replace the instrument cluster. Refer to Instrument Cluster Replacement in Instrument Panel, Gages and Console. Is the repair complete? | -- | -- | |
Is Fuse 21 good? | -- | |||
Is Fuse 21 good? | -- | |||
Is the measured resistance less than the specified value? | OL | |||
17 |
Is the repair complete? | -- | -- | |
18 | Install Fuse 21. Is the repair complete? | -- | -- | |
Inspect the SDM wiring harness connector. Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement . Is the connector secure? | -- | |||
20 |
Is the repair complete? | -- | -- | |
21 |
Is the SDM wiring harness connector terminal 10 damaged or corroded? | -- | ||
22 | Replace the SDM wiring harness connector. Refer to Wiring Repair . Is the repair complete? | -- | -- | |
23 | Inspect the SDM terminals for damage or corrosion. Are any terminals damaged or corroded? | -- | ||
24 | Replace the SDM. Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement . Is the repair complete? | -- | -- | |
Use the J 39200 to measure the resistance between the output side of Fuse 21 and terminal 10 of the SDM wiring harness connector. Is the measured resistance within the specified value? | 0-2 ohms | |||
26 |
Is the repair complete? | -- | -- | |
Is the measured voltage within the specified value? | B+ | Go to Power Distribution Schematics in Wiring Systems | ||
28 | Reconnect all the SIR system components, making sure all the components are properly mounted. Have all the SIR components been reconnected and properly mounted? | -- | -- |