Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you review the HVAC operation and perform the necessary inspections? | -- | Go to Step 2 | Go to Symptoms |
2 | Inspect the LO BLOWER fuse in the fuse block. Is the LO BLOWER fuse open? | -- | Go to Step 3 | Go to Step 6 |
3 | Inspect for a short to ground in circuit 141 (BRN). Refer to Testing for Short to Ground in Wiring Systems. Is a short to ground in the circuit? | -- | Go to Step 4 | Go to Step 5 |
4 | Locate and repair the short to ground in circuit 141 (BRN). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 14 | -- |
5 | Replace the Heater-A/C control. Refer to Control Assembly Replacement . Is the repair complete? | -- | Go to Step 14 | -- |
6 |
Does the test lamp light ? | -- | Go to Step 7 | Go to Step 3 |
7 |
Does the test lamp light? | -- | Go to Step 8 | Go to Step 11 |
8 | Use a test light in order to backprobe between the blower motor connector terminal A and terminal B. Does the test lamp light? | -- | Go to Step 9 | Go to Step 10 |
9 | Replace the blower motor. Refer to Blower Motor and Fan Replacement . Is the repair complete? | -- | Go to Step 14 | -- |
10 |
Does the test lamp light? | -- | Go to Step 11 | Go to Step 12 |
11 | Replace the blower motor resistor. Refer to Blower Motor Resistor Replacement in Heating, Ventilation, and Air Conditioning. Is the repair complete? | -- | Go to Step 14 | -- |
12 | Repair poor connector or open in circuit 150 (BLK) between the blower motor resistor connector C1 terminal E and G200. Is the repair complete? | -- | Go to Step 14 | -- |
13 | Repair a poor connection or an open in circuit 141 (BRN). Refer to Testing for Intermittent Conditions and Poor Connections and Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 14 | -- |
14 | Verify that the system operates properly. Does the system operate properly? | -- | System OK | Go to Symptoms |