Temperature Actuator Replacement LH
Removal Procedure
- Remove the left instrument panel insulator. Refer to
Instrument Panel Insulator Replacement
in Instrument Panel
Gauges and Console.
- Remove the knee bolster. Refer to
Knee Bolster Bracket Replacement
in Instrument Panel, Gauges
and Console.
- Disconnect the electrical
connector from the temperature actuator.
- Remove the HVAC Con (HVAC Control) MiniFuse #27 from the IP electrical
center.
- Remove the HVAC
- Remove the mounting bolts from the temperature actuator.
- Remove the temperature
actuator.
Installation Procedure
- Position the temperature
actuator, then align the slots in the electric actuator driver to the flats
on the temperature valve shaft.
- Slide the electric actuator driver onto the shaft, while aligning
the actuator locating hole to the forward alignment pin on the HVAC control
module case. The actuator driver should completely seat onto the
temperature valve shaft and the mounting holes should be flush with
the mounting bosses on the HVAC control module case.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the mounting
bolts to the temperature actuator.
Tighten
Tighten the temperature actuator bolts to 1.5 N·m (13 lb in).
- Connect the electrical
connector to the temperature actuator.
- Install the knee bolster. Refer to
Knee Bolster Bracket Replacement
in Instrument Panel, Gauges
and Console.
- Install the left instrument panel insulator. Refer to
Instrument Panel Insulator Replacement
in Instrument Panel
Gauges and Console.
- Install the HVAC Con (HVAC Control) MiniFuse #27 from the IP electrical
center.
Important: The HVAC control module must be recalibrated after actuator replacement.
- With a scan tool, perform the recalibrate all motors command in instrument
panel module special functions.