Removal Procedure
- Remove the fuel sender
assembly. Refer to
Fuel Sender Assembly Replacement
.
- Inspect the position of
the fuel strainer (4) for installation.
- Support the reservoir with one hand and grasp the fuel strainer
with the other hand.
- Place the fuel sender assembly upside down on a bench.
- Disconnect the fuel sender assembly electrical connectors from
the fuel sender cover assembly.
- Pinch in the retainer tabs on the fuel level sensor assembly (5)
and remove the fuel level sensor.
Installation Procedure
- Install the new fuel level
sensor assembly (5) on to the fuel sender (2).
- Connect the fuel level sensor electrical connectors to the fuel
sender cover assembly.
- Install the fuel sender
assembly. Refer to
Fuel Sender Assembly Replacement
.