If the source of the leak
is not obvious, use a water test stand and perform generalized leak test method.
Once the general leak area is located, use a water hose or an air hose and
perform one of the localized test procedures to pinpoint the specific leak
area. Refer to
Water Hose Test
or
Air Hose Test
.
- Subject the vehicle to a water spray of 155 KPa (22 psi)
for 10 to 20 minutes.
- When testing the windshield, set the stands 60 cm (24 in)
from the corner of the windshield with the nozzles pointing approximately
30 degrees down and 30 degrees toward the rear of the vehicle.
- When testing the side of the vehicle, set the stands so the nozzles
point approximately 30 degrees down and 45 degrees toward the
rear of the vehicle.
- When testing the rear window and rear compartment lid, set the
stands 60 cm (24 in) from the corner of the rear window with
the nozzles pointing approximately 30 degrees down and 30 degrees
toward the front of the vehicle.