Step | Action | Yes | No |
---|---|---|---|
1 |
Is vacuum present? | Go to Step 2 | Go to Step 11 |
2 |
Do all the lines hold vacuum? | Go to Step 3 | Go to Step 10 |
3 | Inspect the actuator doors for binding. Did you find and correct the condition? | Go to Step 20 | Go to Step 4 |
4 |
Does the test lamp illuminate? | Go to Step 5 | Go to Step 9 |
5 |
Did the test lamp illuminate only when the VENT, FRONT, MAX or NORM buttons were pushed? | Go to Step 6 | Go to Step 12 |
6 |
Did the test lamp illuminate only when the OFF or HTR buttons were pushed? | Go to Step 7 | Go to Step 13 |
7 |
Did the test lamp illuminate only when the OFF or HTR buttons were pushed? | Go to Step 8 | Go to Step 14 |
8 |
Did the test lamp illuminate only when the MAX button was pushed? | Go to Step 17 | Go to Step 15 |
9 | Repair the open or short to ground on circuit 41 | Go to Step 20 | -- |
10 | Inspect each vacuum line for an open or restriction, if no open or restriction was found replace the appropriate actuator. | Go to Step 20 | -- |
11 | Locate condition and restore vacuum to source line. | Go to Step 20 | -- |
12 | Inspect CKT 1396 for an open, short to ground, short to voltage or high resistance. Did you find and correct the condition? | Go to Step 20 | Go to Step 16 |
13 | Inspect CKT 1397 for an open, short to ground, short to voltage or high resistance. Did you find and correct the condition? | Go to Step 20 | Go to Step 16 |
14 | Inspect CKT 1394 for an open, short to ground, short to voltage or high resistance. Did you find and correct the condition? | Go to Step 20 | Go to Step 16 |
15 | Inspect CKT 1395 for an open, short to ground, short to voltage or high resistance. Did you find and correct the condition? | Go to Step 20 | Go to Step 16 |
16 | Inspect for poor connections at the harness connector of the Heater and A/C Control Assembly. | Go to Step 20 | Go to Step 18 |
17 | Inspect for poor connections at the harness connector of the Heater and A/C Vacuum Valve. | Go to Step 20 | Go to Step 19 |
18 | Replace the Heater and A/C Control Assembly. | Go to Step 20 | -- |
19 | Replace the Heater and A/C Vacuum Valve. | Go to Step 20 | -- |
20 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | -- |