Removal Procedure
- Remove the instrument panel assembly. Refer to
Instrument Panel Assembly Removal
in Instrument Panel, Gauges and Console.
- Remove the temperature
valve link rod (1) from the temperature valve by snapping the rod out
of the valve.
- Disconnect the electrical connector (3) from the A/C temperature
valve actuator (4).
- Remove the screws (2) which retain the actuator to the
heater and A/C module (5).
- Remove the actuator.
Installation Procedure
- Install the A/C temperature
and valve actuator (4) to the heater and A/C module (5).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the screws (2).
Tighten
Tighten the screws to 1.4 N·m (12 lb in).
- Connect the electrical connector (3) to the A/C temperature
valve actuator.
Important: Adjust the temperature valve link rod prior to installation. Refer to
Temperature Valve Link Adjustment
.
- Install the temperature valve link rod (1) to the temperature
valve, by snapping the rod into place.
- Install the instrument panel assembly. Refer to
Instrument Panel Assembly Removal
in Instrument Panel, Gauges and Console.