Removal Procedure
- Remove the right sound insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel
Gauges and Console.
- Disconnect the lower electrical
connector.
2.1. | Press down on the center tab of the multi-use bracket (1). |
2.2. | Slide the module (3) downward until the mounting rails
are disengaged. |
- Disconnect the upper electrical connector.
Installation Procedure
Important: Carefully follow the installation procedure when replacing the RFA module
in order to avoid malfunctions or inoperative options. If the RPO options
are improperly set, the RFA system may become inoperative.
- Connect the upper electrical connector.
1.1. | Align the mounting rails on the module (3) with the mounting
rails on the multi-use bracket (1). |
1.2. | Slide the module (3) upward into place until the mounting
rails align and the locking tab engages. |
- Connect the lower electrical connector.
- Install the right sound insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel
Gauges and Console.
- Program the RFA module. Refer to
Remote Control Door Lock Reprogramming
.
- Program the transmitters. Refer to
Transmitter Programming
.