Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Instrument Cluster System Check? | -- | Go to Step 2 | |
2 |
Does the TRUNK AJAR indicator illuminate? | -- | Go to Step 3 | Go to Step 4 |
3 | Connect a fused jumper between switch connector terminal B and terminal C. Does the TRUNK AJAR indicator illuminate? | -- | Go to Step 5 | Go to Step 6 |
4 | Inspect for an open in CKT 744 (RED/BLK). Is the wiring OK? | -- | Go to Step 11 | Go to Step 10 |
5 | Inspect the rear compartment lid latch switch connector for proper terminal contact. Is the terminal contact OK? | -- | Go to Step 8 | Go to Step 7 |
6 | Inspect for an open in CKT 1350 (BLK/WHT). Is the wiring OK? | -- | Go to Step 9 | |
7 | Repair the poor terminal contact. Did you complete the repair? | -- | -- | |
8 | Replace the rear compartment lid latch switch. Did you complete the repair? | -- | -- | |
9 | Repair the open CKT 1350 (BLK/WHT). Did you complete the repair? | -- | -- | |
10 | Repair the open in CKT 744 (RED/BLK). Did you complete the repair? | -- | -- | |
11 |
Are the connector terminal contacts OK? | -- | Go to Step 12 | Go to Step 7 |
12 | Replace the instrument cluster. Did you complete the repair? | -- | -- |