Removal Procedure
- Remove the case side cover. Refer to
Control Valve Body Cover Replacement
.
- Use a small flat-bladed
tool in order to remove the wiring harness (224) from the case electrical
connector (35).
- Use a small flat-bladed
tool in order to remove the wiring harness from the solenoid valve(s) and/or
the sensor.
- Remove the oil pump in order to access the Torque Converter Clutch
(TCC) Pulse Width Modulated (PWM) solenoid (325). Refer to
Oil Pump Replacement
.
- Remove the clips retaining the solenoid(s).
- Remove the solenoid(s).
- Remove the 2-3 shift solenoid (315).
- Inspect the wiring harness (224) for the following:
• | Bent or broken electrical connectors |
Installation Procedure
- Install the 2-3 shift solenoid (315).
- Install the solenoid(s).
- Install the retaining clips.
- Install the oil pump, if removed. Refer to
Oil Pump Replacement
.
- Install the wiring harness to the electrical connector in the case,
the solenoid valve(s) and/or the sensor.
- Install the case side cover. Refer to
Control Valve Body Cover Replacement
.