Important: The HVAC module assembly retaining screw is located under the HVAC module assembly mounting bracket.
Important: The HVAC module assembly retaining screw is located under the heater core.
Important: The evaporator temperature sensor must be located in the same position on the new evaporator core.
Important: Flat washer type seals do not require lubrication.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the screws to 3.2 N·m (28 lb in).
Important: Align the evaporator temperature sensor wires with the opening in the upper HVAC module case. Improper alignment will pinch and/or cut the sensor wires.
Tighten
Tighten the screws to 0.9 N·m (8 lb in).
Tighten
Tighten the screw to 0.9 N·m (8 lb in).
Tighten
Tighten the screw to 0.9 N·m (8 lb in).
Tighten
Tighten the screws to 0.9 N·m (8 lb in).
Tighten
Tighten the screws to 0.9 N·m (8 lb in).
Tighten
Tighten the screw to 0.9 N·m (8 lb in).
Tighten
Tighten the screws to 1.8 N·m (16 lb in).
Tighten
Tighten the screws to 0.9 N·m (8 lb in).