Tools Required
J 39400-A Halogen
Leak Detector
Removal Procedure
- Remove the auxiliary HVAC module assembly. Refer to
Auxiliary HVAC Module Replacement
.
- Remove the auxiliary TXV. Refer to
Auxiliary Air Conditioning Evaporator Thermal Expansion Valve Replacement
.
- Remove the auxiliary blower
motor housing screws.
- Remove the auxiliary blower motor housing from the HVAC module.
- Remove the auxiliary HVAC module case screws.
- Separate the auxiliary HVAC module case halves.
- Remove the auxiliary evaporator core from the lower HVAC module
case.
Installation Procedure
- If replacing the auxiliary evaporator core add the specified amount
of PAG oil directly to the auxiliary evaporator core. Refer to
Refrigerant System Capacities
.
- Install the auxiliary evaporator core into the lower HVAC module
case.
- Assemble the auxiliary HVAC module case halves.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the auxiliary
HVAC module case screws.
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
- Install the auxiliary
blower motor housing to the HVAC module.
- Install the auxiliary blower motor housing screws.
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
- Install the auxiliary TXV. Refer to
Auxiliary Air Conditioning Evaporator Thermal Expansion Valve Replacement
.
- Install the auxiliary HVAC module assembly. Refer to
Auxiliary HVAC Module Replacement
.
- Leak test the fittings of the component using J 39400-A
.