Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Fog Lights Schematics Connector End View Reference: Master Electrical Component List in Wiring Systems. | |||
1 | Did you perform the Lighting System Diagnostic System Check? | Go to Step 2 | |
2 |
Do the fog lamps illuminate? | Go to Fog Lamps Always On | Go to Step 3 |
3 | Observe the fog lamp indicator of the instrument panel cluster (IPC). Does the IPC fog lamp indicator illuminate? | Go to Step 4 | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems |
4 | Inspect for poor connections at the harness connector of the instrument panel cluster. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 6 | Go to Step 5 |
5 |
Important: Perform the set up procedure for the IPC. Replace the IPC. Refer to Instrument Cluster Replacement in Instrument Panel, Gages, and Console. Did you complete the replacement and the set up procedure? | Go to Step 6 | -- |
6 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |