Tools Required
J 39400-A Halogen Leak Detector
Removal Procedure
- Recover the refrigerant from the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Remove the condenser. Refer to
Condenser Replacement
.
- Remove the receiver dehydrator upper bracket bolt.
- Remove the receiver dehydrator lower mounting bolts.
- Remove the receiver dehydrator.
- Remove and discard the sealing washers.
Installation Procedure
- If replacing the receiver dehydrator add the specified amount of PAG oil directly to the receiver dehydrator. Refer to
Refrigerant System Capacities
.
- Install new sealing washers for the receiver dehydrator. Refer to
Sealing Washer Replacement
.
- Install the receiver dehydrator to the condenser.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the receiver dehydrator lower mounting bolts.
Tighten
Tighten the nuts to 6 N·m (53 lb in).
- Install the receiver dehydrator upper bracket bolt.
Tighten
Tighten the bolts to 6 N·m (53 lb in).
- Install the condenser. Refer to
Condenser Replacement
.
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Leak test the fittings of the component using J 39400-A
.