Table 1: | Body Control Module (BCM) |
Table 2: | Instrument Panel Cluster (IPC) |
Scan Tool Output Control | Additional Menu Selection(s) | Description |
---|---|---|
Interior Lamps | Output Control/Lamp Test | The body control module (BCM) turns the interior lamps ON when you select ON. The interior lamps should stay ON until commanded OFF. |
I/P Illumination Lamps | Output Control/Lamp Test | The BCM turns the instrument panel illumination lamps on when you select ON. The illumination lamps should stay on until commanded OFF. |
Transmission Range Indicator | Output Control/Lamp Test | The BCM turns the PRNDL indicators ON when you select ON. The PRNDL should stay ON until commanded OFF. |
Scan Tool Output Control | Additional Menu Selection(s) | Description | ||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lamp and Gauge Check | The instrument panel cluster (IPC) illuminates the following indicators when you select ON:
The IPC drives the following gages to maximum position when you select ON:
The indicators should stay illuminated and all gages remain at maximum until commanded OFF. When commanded OFF, the indicators should turn OFF and all gages should remain at the minimum position until the test is exited or commanded ON. |
Scan Tool Output Control | Additional Menu Selection(s) | Description |
---|---|---|
All Telltales Test | Body / IPC / Actuator Test | The instrument panel cluster (IPC) illuminates all the indicators. |
Telltale Test | Body / IPC / Actuator Test | The instrument panel cluster (IPC) illuminates individual indicators. |
Control Test | Body / IPC / Actuator Test | The instrument panel cluster (IPC) illuminates individual gauges. |
Illumination Test | Body / IPC / Actuator Test | The BCM turns the instrument panel illumination lamps on when you select ON. The illumination lamps should stay on until commanded OFF. |