Step | Action | Values | Yes | No |
---|---|---|---|---|
1 | Check other instrumentation lights. Are those lights also off? | -- | Go to Step 2 | |
2 |
Is the voltage within the specified value? | 11-14 V | Go to Step 4 | Go to Step 3 |
3 | Repair the wiring harness between J6 terminal 3 and controller connector terminal A4. Is the repair complete? | -- | System OK | -- |
4 | Check the illumination lamps. Is one burned out? | -- | Go to Step 5 | Go to Step 6 |
5 | Replace the burned out illumination lamp. Is the repair complete? | -- | System OK | -- |
6 | Replace the ATC controller. Is the repair complete? | -- | System OK | -- |