• | DT-48616 Control Solenoid Test Plate |
• | DT-48616-10 Adapter Harness |
The purpose of this procedure is to test the functionality of the control solenoid (with body and TCM) valve assembly solenoids for a gross stuck open or stuck closed condition. DT-48616 Control Solenoid Test Plate is bolted to the control solenoid (with body and TCM) valve assembly on the valve body mounting surface. Pressurized air is passed into the aluminum test block, through the control solenoid (with body and TCM) valve assembly solenoid passage and back to a pressure gage on the test block. The pressure gage indicates open if air pressure is passed through the solenoid, or closed if the solenoid is unable to pass air through. A scan tool is used to command the solenoids ON and OFF. While watching the pressure gage, one can determine the valve functionality. The recommended shop air pressure for this test is 90-100 psi.
Caution: Do not energize the solenoids for more than two minutes or the solenoids could be damaged.
Component | Port On Test Block | Key On, Engine Off (KOEO) Normal State |
---|---|---|
PC Solenoid 2, 35R | F | Full PSI flow to gage |
PC Solenoid 3, R1/456 | G | Full PSI flow to gage |
PC Solenoid 4, 2-6 | B | No PSI flow to gage |
PC Solenoid 5, 1234 | C | No PSI flow to gage |
Shift Solenoid | D | Full PSI flow to gage |
Line Pressure Control Solenoid | A | Full PSI flow to gage |
TCC PC Solenoid | E | No PSI flow to gage |
Note: With the key on engine off (KOEO), the TCM will normally cycle some of the transmission solenoids On and Off to facilitate keeping the ports and solenoids clean and free of debris. This dither function is a normal activity and will cause the valves to cycle open and closed quickly when the TCM is powered up. This can cause the psi gage to flicker high and low as the valves open and close. This may cause some air to exit the ports where the psi gage is not connected as those solenoids cycle on and off.
Drain the TCM of excess transmission fluid before attaching to test block and use caution when attaching air to test block air inlet.