Step | Action | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air does not flow correctly from the air distribution outlets. | |||||||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |||||||||||
2 | Place the blower motor switch in each speed position. Does the blower motor operate in each speed position? | Go to Step 3 | Go to Blower Motor Malfunction | ||||||||||
3 | Are all of the HVAC control assembly controls except for the blower motor inoperative? | Go to Step 13 | Go to Step 4 | ||||||||||
4 |
Does the recirculation door move from the recirculation to the outside air position? | Go to Step 5 | |||||||||||
5 |
Does air flow sufficiently from the proper air distribution outlets for each selected mode position? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 6 | ||||||||||
6 | Inspect the air delivery system for the following conditions:
Did you find and correct the condition? | Go to Step 19 | Go to Step 7 | ||||||||||
7 | Inspect the mode door and the mode actuator for the following conditions:
Did you find and correct the condition? | Go to Step 19 | Go to Step 8 | ||||||||||
8 | Test the position signal circuit of the mode actuator for an open or for a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 19 | Go to Step 9 | ||||||||||
9 | Test the low reference circuit of the mode actuator for an open or for a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 19 | Go to Step 10 | ||||||||||
10 | Test the 5-volt reference circuit of the appropriate mode actuator for an open or for a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 19 | Go to Step 11 | ||||||||||
11 |
Does the test lamp illuminate in both positions? | Go to Step 15 | Go to Step 12 | ||||||||||
12 | Test the mode door control A and mode door control B circuits of the mode actuator for an open, a high resistance, a short to ground, or a short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 19 | Go to Step 16 | ||||||||||
13 | Test the voltage circuits of the HVAC control assembly for an open or for a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 19 | Go to Step 14 | ||||||||||
14 | Test the ground circuit of the HVAC control assembly for an open or for a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 19 | Go to Step 16 | ||||||||||
15 | Inspect for bad connections at the harness connector of the mode actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 19 | Go to Step 17 | ||||||||||
16 | Inspect for bad connections at the harness connector of the HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 19 | Go to Step 18 | ||||||||||
17 | Replace the mode actuator. Refer to Mode Actuator Replacement . Did you complete the replacement? | Go to Step 19 | -- | ||||||||||
18 | Replace the HVAC control assembly. Refer to Heater and Air Conditioning Control Replacement . Did you complete the replacement? | Go to Step 19 | -- | ||||||||||
19 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 6 |