Circuit Description
The GMLAN serial data circuits are controller area network (CAN) high and/or low speed serial data buses used to communicate information between the control modules. Typical data transmission speeds must be high enough to ensure that a required real-time
response is maintained. There are two different types of GMLAN serial data circuits, the High speed 2-wire circuit and Low speed single wire circuit. The GMLAN serial data circuits also communicate directly to the data link connector (DLC). Messages are interpreted
by the externally connected CANdi module which acts as a transceiver for the scan tool.
Modules connected to the GMLAN serial data circuits monitor communications during normal vehicle operation, where operation information is exchanged among the modules. All the modules on the GMLAN networks, maintain a transmit error counter (TEC) and a
receive error counter (REC). The counter values increase with detected errors and will decrease with error-free messages.
DTC Descriptors
DTC U0073: Controller Area Network (CAN) Bus Communication
DTC U2100: Controller Area Network (CAN) Bus Communication
Conditions for Running the DTC
• | Supply voltage to the modules are in the normal operating range. |
• | The vehicle is in the RUN power mode. |
Conditions for Setting the DTC
The module setting the DTC has attempted to establish communications on the GMLAN circuits for more than 7 times.
Action Taken When the DTCs Sets
• | The module suspends all message transmission. |
• | The module uses default values for all parameters received on the serial data circuits. |
• | The module inhibits the setting of all other communication DTCs. |
Conditions for Clearing the DTC
• | A current DTC clears when the malfunction is no longer present. |
• | A history DTC clears when the module ignition cycle counter reaches the reset threshold, without a repeat of the malfunction. |
Diagnostic Aids
This DTC cannot be retrieved with a current status. Diagnosis of a current DTC is accomplished via
Scan Tool Does Not Communicate with High Speed GMLAN Device
. Refer to
Data Link References
for the correct procedure for the specific module(s) and the busses they use to communicate.
Reference Information
Schematic Reference
Data Communication Schematics
Connector End View Reference
Component Connector End Views
Description and Operation
Data Link Communications Description and Operation
Electrical Information Reference
Scan Tool References
Control Module References
for Scan Tool Information