• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
HVAC Module B+ | 1 | 1 | -- | -- |
HVAC Relay B+ | 1 | 1 | -- | -- |
HVAC Module Ignition | 1 | 1 | -- | -- |
Blower Motor Ignition | 1 | 1 | -- | -- |
Blower Motor High Speed Relay Coil Ignition | 1 | 2 | -- | -- |
High Speed Blower Motor Control | 6 | 2 | -- | -- |
Blower Motor Control | 6 | 1 | 1 | -- |
Blower Motor High Speed Relay Coil Control | 6 | 2 | -- | -- |
Blower Motor Medium 2 Control | 6 | 3 | -- | -- |
Blower Motor Medium 1 Control | 6 | 4 | -- | -- |
Blower Motor Low Speed Control | 6 | 5 | -- | -- |
Blower Motor Switch Ground | -- | 1 | -- | -- |
Blower Motor High Speed Relay Switch Ground | -- | 2 | -- | -- |
HVAC Module Ground | -- | 1 | -- | -- |
1. Blower Motor Inoperative - All 2. Blower Motor Inoperative - High 3. Blower Motor Inoperative - Medium 2 4. Blower Motor Inoperative - Medium 1 5. Blower Motor Inoperative - Low 6. Blower Motor Always ON |
The HVAC control assembly applies a ground to the blower motor control circuit that corresponds to the selected blower speed. The resistors and the blower motor are in a series circuit. The following list represents the number of resistors in series with the blower motor per particular speed request:
• | Low speed, 3 resistors |
• | Medium 1 speed, 2 resistors |
• | Medium 2 speed, 1 resistors |
When the operator requests high speed, the HVAC control assembly applies ground to the high speed blower relay control circuit. When the relay contacts close, ground is applied directly to the blower motor through the blower motor resistor.
Manual HVAC Description and Operation
Control Module References for scan tool information
⇒ | If the HVAC relay does not turn on, refer to the HVAC Relay Malfunction. |
⇒ | If the blower motor does not function properly in the High speed position, refer to High Speed Blower Malfunction. |
⇒ | If the blower motor does not function properly in each speed position, refer to Blower Malfunction. |
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. |
⇒ | If the test lamp does not illuminate, replace the BCM. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp does not illuminate, test the B+ circuit for short to ground or an open/high resistance. |
⇒ | If the test lamp does not illuminate, test the ignition circuit for short to ground or an open/high resistance. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. If the circuit tests normal, test or replace the HVAC control module. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp does not illuminate, test the ignition circuit for a short to ground or an open/high resistance. If the circuit tests normal, test or replace the HVAC relay. |
⇒ | If greater than the specified range, test the control circuit for an open/high resistance. If the circuit tests normal, test or replace the high speed blower relay. |
⇒ | If the test lamp does not illuminate test the ignition circuit for an open/high resistance. |
⇒ | If the test lamp does not illuminate, test the control circuit for an open/high resistance. If the circuit test normal, test or replace the blower motor resistor. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp does not illuminate, test the appropriate control circuit for a short to ground or an open/high resistance. If the circuit test normal, test or replace the HVAC control module. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.